AEDASS-H-3005
● VIP type case consisting of Two Gases 230 mm Rota-meter Oxygen and Nitrous Oxide.
● Halothane Vaporizer Goldman Type cum outlet complete with open circuit attachment.
● Rotameter inlet connection attached with Pressure Tube connecting preset Regulators for direct fitting to the Cylinders.
AEDASS-H-3007
● VIP type case consisting of Two Gases 230 mm Rota-meter Oxygen and Nitrous Oxide.
● Halothane Vaporizer Goldman Type cum outlet complete with open circuit attachment.
● Rotameter inlet connection attached with Pressure Tube connecting preset Regulators for direct fitting to the Cylinders.
SAFETY FEATURES
» N₂O Automatic Cut Off in case failure of Oxygen Supply.
» Oxygen Failure Alarm.
» Hypoxic-Guard-Device.
AEDASS-H-3012
● Two Gases 230 mm Rota-meter Oxygen and Nitrous Oxide.
● Halothane Vaporizer Goldman Type.
● Emergency Unit cum outlet complete with open circuit attachment.
● Provision for fitting Two 'B' type cylinders at the back side complete with One Drawer on Four caster wheels.
AEDASS-H-3012-E
● Provision for four cylinders attachment.
● Two Gases 230 mm Rota-meter Oxygen and Nitrous Oxide.
● Halothane Vaporizer Goldman Type.
● Emergency Unit cum outlet complete with open circuit attachment.
● Provision for fitting Two 'B' type cylinders at the back side complete with One Drawer on Four caster wheels.
AEDASS-H-3015
● Two gases Rotometr Oxygen and Nitrous Oxide with Hyposic-Guard Devices.
● Oxygen Flowmeter Range 100cc/min. to 10 ltrs./min. Nitrous Oxide Flowmeter range 200cc/min. to 12 ltrs/min.
● Standard Fresh Gas Outlet.
● Change over system open circuit to close circuit.
● Emergency Flush valve at front Panel connected to incoming O₂ supply.
● Goldman type Halothane Vaporizer.
● Parking space for two additional Vaporizers.
● Non-return cum pressure relief valve minimize risk of back flow of gasses.
● Blows off valve when pressure exceeds 200 cm of water column fitted.
● Provision to fit ventilator.
● Provision to fit carbon Dioxide Absorber.
● Extended platform at rear for two 'B' type cylinder.
● Table top made of Stainless Steel.
● Top Tray provided at eye level for keeping monitoring equipments.
● Maggill's or Bains circuit.
● One spacious Drawer on smooth runner.
● Four castor trolley with front two lockable wheels.
● Pin index yokes two for Oxygen and two for Nitrous Oxide.
● High-efficiency Regulators for reliability two each for O₂ and N₂O.
SAFETY FEATURES
» N₂O Automatic Cut Off in case failure of Oxygen Supply.
» Low pressure Oxygen addible Alarm.
Major Anesthesia Machine (Stainless Steel Square Frame)
Product Code : AEDASS-H-3015-S
Major Anesthesia Machine (Stainless Steel Square Frame)
AEDASS-H-3015-S
● Two gases Rotometr Oxygen and Nitrous Oxide with Hyposic-Guard Devices.
● Oxygen Flowmeter Range 100cc/min. to 10 ltrs./min. Nitrous Oxide Flowmeter range 200cc/min. to 12 ltrs/min.
● Standard Fresh Gas Outlet.
● Change over system open circuit to close circuit.
● Emergency Flush valve at front Panel connected to incoming O₂ supply.
● Goldman type Halothane Vaporizer.
● Parking space for two additional Vaporizers.
● Non-return cum pressure relief valve minimize risk of back flow of gasses.
● Blows off valve when pressure exceeds 200 cm of water column fitted.
● Provision to fit ventilator.
● Provision to fit carbon Dioxide Absorber.
● Extended platform at rear for two 'B' type cylinder.
● Table top made of Stainless Steel.
● Top Tray provided at eye level for keeping monitoring equipments.
● Maggill's or Bains circuit.
● One spacious Drawer on smooth runner.
● Four castor trolley with front two lockable wheels.
● Pin index yokes two for Oxygen and two for Nitrous Oxide.
● High-efficiency Regulators for reliability two each for O₂ and N₂O.
SAFETY FEATURES
» N₂O Automatic Cut Off in case failure of Oxygen Supply.
» Low pressure Oxygen addible Alarm.
AEDASS-H-3015-P
● Two gases Rotometr Oxygen and Nitrous Oxide with Hyposic-Guard Devices.
● Oxygen Flowmeter Range 100cc/min. to 10 ltrs./min. Nitrous Oxide Flowmeter range 200cc/min. to 12 ltrs/min.
● Standard Fresh Gas Outlet.
● Change over system open circuit to close circuit.
● Emergency Flush valve at front Panel connected to incoming O₂ supply.
● Goldman type Halothane Vaporizer.
● Parking space for two additional Vaporizers.
● Non-return cum pressure relief valve minimize risk of back flow of gasses.
● Blows off valve when pressure exceeds 200 cm of water column fitted.
● Provision to fit ventilator.
● Provision to fit carbon Dioxide Absorber.
● Extended platform at rear for two 'B' type cylinder.
● Table top made of Stainless Steel.
● Top Tray provided at eye level for keeping monitoring equipments.
● Maggill's or Bains circuit.
● One spacious Drawer on smooth runner.
● Four castor trolley with front two lockable wheels.
● Pin index yokes two for Oxygen and two for Nitrous Oxide.
● High-efficiency Regulators for reliability two each for O₂ and N₂O.
SAFETY FEATURES
» N₂O Automatic Cut Off in case failure of Oxygen Supply.
» Low pressure Oxygen addible Alarm.
Major Anesthesia Machine (Stainless Steel Square Frame) Hypoxic Guard Device
Product Code : AEDASS-H-3015-H
Major Anesthesia Machine (Stainless Steel Square Frame) Hypoxic Guard Device
AEDASS-H-3015-H
● Two gases Rotometr Oxygen and Nitrous Oxide with Hyposic-Guard Devices.
● Oxygen Flowmeter Range 100cc/min. to 10 ltrs./min. Nitrous Oxide Flowmeter range 200cc/min. to 12 ltrs/min.
● Standard Fresh Gas Outlet.
● Change over system open circuit to close circuit.
● Emergency Flush valve at front Panel connected to incoming O₂ supply.
● Goldman type Halothane Vaporizer.
● Parking space for two additional Vaporizers.
● Non-return cum pressure relief valve minimize risk of back flow of gasses.
● Blows off valve when pressure exceeds 200 cm of water column fitted.
● Provision to fit ventilator.
● Provision to fit carbon Dioxide Absorber.
● Extended platform at rear for two 'B' type cylinder.
● Table top made of Stainless Steel.
● Top Tray provided at eye level for keeping monitoring equipments.
● Maggill's or Bains circuit.
● One spacious Drawer on smooth runner.
● Four castor trolley with front two lockable wheels.
● Pin index yokes two for Oxygen and two for Nitrous Oxide.
● High-efficiency Regulators for reliability two each for O₂ and N₂O.
SAFETY FEATURES
» N₂O Automatic Cut Off in case failure of Oxygen Supply.
» Low pressure Oxygen addible Alarm.
AEDASS-H-3020-E
● Long rotating bobbin flowmeter (230mm) tube calibrated.
● Oxygen flowmeter range 100cc/min to 8Ltrs./min Nitrous Oxide Flowmeter Range 200cc/min to 12Ltrs./min
● Plenum type ether vaporizer.
● Goldman type halothene vaporizer.
● Build-in-space for one more vaporizer.
● Non return cum pressure relief valve.
● Fresh gas outlet cum emergency Oxygen unit located at a convent position.
● Provision to fit Ventilator.
● Provision to fit Carbon Dioxide Absorber.
● Provision to accommodate two Nos. 10 Ltrs. Cylinders at the back side.
● Table top made of stainless steel.
● Top tray provided at eye level for keeping monitoring instrument.
● Maggill's or Bains Circuit.
● Fitted with two large diameter gauges each for Oxygen and Nitrous Oxide.
● One spacious Drawer on smooth runner.
● Pin Index Yokes two for Oxygen and two for Nitrous Oxide.
● Change over system for open and close circuit.
● Preset regulator's for O₂ and N₂O two each.
● Shelf for Ampule.
SAFETY FEATURES
» N₂O Automatic Cut Off in case failure of Oxygen Supply.
» Low pressure Oxygen addible mechanical Alarm.
» Hypoxicguard (Rotameter ensure protection against)
» Singular Flow of N₂O Until a minimum flow of 1.5 Ltr. Oxygen is released.
AEDASS-H-3020-S
● Long rotating bobbin flowmeter (230mm) tube calibrated.
● Oxygen flowmeter range 100cc/min to 8Ltrs./min Nitrous Oxide Flowmeter Range 200cc/min to 12Ltrs./min
● Plenum type ether vaporizer.
● Goldman type halothene vaporizer.
● Build-in-space for one more vaporizer.
● Non return cum pressure relief valve.
● Fresh gas outlet cum emergency Oxygen unit located at a convent position.
● Provision to fit Ventilator.
● Provision to fit Carbon Dioxide Absorber.
● Provision to accommodate two Nos. 10 Ltrs. Cylinders at the back side.
● Table top made of stainless steel.
● Top tray provided at eye level for keeping monitoring instrument.
● Maggill's or Bains Circuit.
● Fitted with two large diameter gauges each for Oxygen and Nitrous Oxide.
● One spacious Drawer on smooth runner.
● Pin Index Yokes two for Oxygen and two for Nitrous Oxide.
● Change over system for open and close circuit.
● Preset regulator's for O₂ and N₂O two each.
● Shelf for Ampule.
SAFETY FEATURES
» N₂O Automatic Cut Off in case failure of Oxygen Supply.
» Low pressure Oxygen addible mechanical Alarm.
» Hypoxicguard (Rotameter ensure protection against)
» Singular Flow of N₂O Until a minimum flow of 1.5 Ltr. Oxygen is released.
AEDASS-H-3028-E
● Two gases Rotameter Oxygen and Nitrous Oxide.
● Oxygen flowmeter Range 100cc/min. To 10 liters/min. Nitrous Oxide Flowmeter range 200cc/min. To 10 liters/min.
● Goldman Halothane Vaporizer.
● Built-in-Parking space for two additional vaporizer.
● Circle Absorber with transparent Canister.
● Non return cum pressure relief value to minimize risk of back flow of gases.
● Blows of value when pressure exceeds 200cm of water column fitted.
● Emergency push Button at front Panel connected to incoming O² supply. (Oxygen Push Button ensures free flow of Oxygen at 35-45 liters at 3.8 bar)
● Table Top made of stainless steel
● Top tray provided at eye level for keeping Monitoring Equipments
● Two self-sealing Quick Coupling Type Gas Outlets One each for O²N²O at the rear side for central pipe line connection
● Separate Oxygen flow meter for independent Oxygen supply
● Sline Stand Locate above right side of Trolley Provision to Fit Ventilator
● Extended platform at rear to accommodate Two 'B' Type Cylinders